Delta-Macro-pump-ksb
Delta-Macro-pump-ksb

Main applications ksb delta macro

  • Building services
  • Fire fighting and sprinkler systems
  • Irrigation
  • Pressure boosting, fire fighting systems
  • Water supply

Technical data

  • Q max 960.0 m³/h
  • H max 154.0 m

Design ksb delta macro

Fully automatic package pressure booster system with two to four (F) / six (VC/SVP) vertical high-pressure pumps; available in cascade-controlled and two variable speed versions. Cascade control (F) for ensuring the required supply pressure. The frequency inverter operated VC and SVP versions ensure variable speed control of each pump via cabinet-mounted frequency inverter (VC) or PumpDrive variable speed system and KSB SuPremE motor (SVP), respectively, providing fully electronic control to ensure the required supply pressure. Automated with BoosterControl

Application pump ksb delta macro

Pressure boosting in residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.

Drive pump ksb delta macro

KSB Delta Macro F, VC:
▪ Electric motor
▪ Efficiency class IE3 to IEC 60034-30
KSB Delta Macro SVP:
▪ Magnetless synchronous reluctance motor
▪ Efficiency class IE5 to IEC 60034-30
▪ KSB SuPremE

Desing Details ksb delta macro

  • Compact system mounted on a common base frame
  • 2 (F/SVP/VC) / 3 (F/SVP/VC) / 4 (F/SVP/VC) / 5 (SVP/VC) /6 (SVP/VC) vertical high-pressure centrifugal pumps
  • Hydraulic components made of stainless steel / brass
  • Integrated dry running protection

KSB Delta Macro F:

  • DOL starting
  • Power contactor per pump
  • Discharge-side gate valve per pump For inlet conditions F and M only:
    • Check valve per pump
    • Suction-side gate valve per pump

KSB Delta Macro VC, SVP:

  • With variable-speed system
  • One frequency inverter per pump

Overview of technical data ksb delta macro

Q (50Hz)0.2 – 960.0 (m³/h)
H (50Hz)0.0 – 154.0 (m)
Type of bearingPlain bearings
DriveIEC standardized motor, electric motor
Drive frequency50 Hz
Type of driveElectric motor
Drive voltageLow voltage
Type of installationIn-line
Type of couplingDirect
Type of lubricationGrease / Product lubrication
Max. permissible fluid temperature60.0 (°C)
Pump set locationDry installed
Suitable for drinking waterYes
Type of casingTubular casing
Type of impellerClosed / Radial
Casing material (EN standard)1.4301, 1.4308
Minimum inlet pressure4.0 (bar)
Installation positionVertical
Shaft seal typeMechanical seal
Main applicationsIndustry and process engineering, Water, Building services
Casing materialChrome nickel steel, Cast stainless steel
Maximum drive rating55.0 (kW)
Type of installationStationary
Maximum speed of rotation2900.0 (1/min)
Type of connectionDirect
Operating modeCascade and variable