RHM-pump-KSB
RHM-pump-KSB

Main applications rhm

  • Energy
  • Nuclear Island
  • Nuclear Power Stations

Technical data

  • Q max 300.0 m³/h
  • H max 2,100.0 m

 

Design rhm

Horizontal multistage barrel pull-out pump

Application pump rhm

Core flooding, emergency cooling and residual heat removal systems, chemical and volume control systems, control rod drive systems, high-pressure and medium-pressure safety injection systems, emergency feed water systems, start-up and shut-down feed water systems, high-pressure charging

Overview of technical data rhm

Q (50Hz)0.0 – 300.0 (m³/h)
H (50Hz)0.0 – 2,100.0 (m)
Drive frequency50 Hz /60 Hz
Type of couplingDirect, Gear
Max. permissible fluid temperature180.0 (°C)
StandardASME SECT. III, KTA, RCC-M
Installation positionHorizontal
Shaft seal typeMechanical seal
Main applicationsEnergy
Maximum discharge-side pressure220.0 (bar)
Maximum speed of rotation8000.0 (1/min)