Main applications rhm
- Energy
- Nuclear Island
- Nuclear Power Stations
Technical data
- Q max 300.0 m³/h
- H max 2,100.0 m
Design rhm
Horizontal multistage barrel pull-out pump
Application pump rhm
Core flooding, emergency cooling and residual heat removal systems, chemical and volume control systems, control rod drive systems, high-pressure and medium-pressure safety injection systems, emergency feed water systems, start-up and shut-down feed water systems, high-pressure charging
Overview of technical data rhm
Q (50Hz) | 0.0 – 300.0 (m³/h) |
H (50Hz) | 0.0 – 2,100.0 (m) |
Drive frequency | 50 Hz /60 Hz |
Type of coupling | Direct, Gear |
Max. permissible fluid temperature | 180.0 (°C) |
Standard | ASME SECT. III, KTA, RCC-M |
Installation position | Horizontal |
Shaft seal type | Mechanical seal |
Main applications | Energy |
Maximum discharge-side pressure | 220.0 (bar) |
Maximum speed of rotation | 8000.0 (1/min) |