Amacan-K pump
Amacan-K pump

Main applications

  • Advanced treatment / 3.stage
  • Bio. treatment / 2.stage
  • Drainage pump stations
  • Flood / stormwater holding tanks
  • Flood control
  • Industrial waste water
  • Mech. treatment / 1.stage
  • Mining
  • Municipal waste water
  • Process
  • Sewage treatment plants
  • Surface drainage
  • Suspended solids
  • treatment
  • Waste water
  • Waste water transport

Design

Wet-installed submersible motor pump for installation in discharge tubes, with channel impeller, single-stage, single-entry. ATEX-compliant version available.

Application

Pumping pre-cleaned chemically neutral waste water, industrial effluent, sewage, fluids not containing any stringy substances, pre-treated by screens and overflow sills; as waste water, mixed sewage and activated sludge pumps in waste water treatment plants, irrigation and drainage pumping stations.

Drive

  • Three-phase asynchronous squirrel-cage motor
  • Motors integrated in explosion-proof pump sets are
    supplied in Ex d IIB type of protection.
  • Enclosure: IP68 to EN 60529/IEC529

Shaft seal

  • Two bi-directional mechanical seals in tandem
    arrangement, with liquid reservo

Desing Details

Design

  • Fully floodable submersible pump in discharge tube
    (submersible motor pump)
  •  Not self-priming
  • Close-coupled design
  • Single-stage
  • Vertical installation

Installation

  • Application-oriented installation types

Overview of technical data

Q (50Hz)140.0 – 7,200.0 (m³/h)
H (50Hz)1.0 – 30.0 (m)
Type of bearingRolling element bearings
Casing partitionRadially split
DriveElectric motor
Drive frequency50 Hz /60 Hz
Type of driveElectric motor
Drive voltageLow voltage
Connection to power supply380 V, 400 V, 690 V, 3~
Explosion protectionATEX II 2G T3
No. of impeller entriesSingle entry
Impeller material (EN standard)9.4460, JL 1040
Type of installationClose-coupled
Type of couplingNone
Type of lubricationGrease lubrication
Max. permissible fluid temperature40.0 (°C)
Nozzle positionIn-line
Pump set locationWet well
Shaft material (EN standard)1.4021QT700, C45+N, 1.4057
Suction characteristicsNon-priming
Type of casingTubular casing
Type of impellerMulti-vane impeller, Radial, Closed
Casing material (EN standard)JL 1040
eClass assignment36410103, 36410100, 36410000
Free passage180.0 (mm)
Installation positionVertical
Shaft seal typeMechanical seal
Main applicationsWater, Waste water / sewage, Mining / Dredges
Casing materialCast iron
Maximum drive rating320.0 (kW)
Type of installationStationary
Maximum speed of rotation1200.0 (1/min)