About Pump 4WN

4″ submerged well pump with stainless steel outer casing and Noryl floating impellers, available complete with oil bath motor. EBARA’s compliance with the NEMA standard for motor coupling ensures the product’s high reliability.

Features

  • Silent
  • Practical and easy to use
  • Suitable for horizontal operation

description Pump 4WN

4″ submerged well pump equipped with a special system of Noryl floating impellers that allows an extremely abrasion-resistant configuration.
The 4WN is very quiet, suitable for horizontal operation and available complete with motor in water bath or oil bath.
EBARA’s compliance with the NEMA standard for motor coupling ensures the product’s high reliability.
For further technical information see the Databook

  • Fountains and water features
  • Power supply of autoclaves
  • Firefighting systems
  • Irrigation
  • Pressurisation

Overview of technical data 4WN

Flow rateUp to 24 m³/h
Total headUp to 300 m
Max. temperature of the liquid+35°C (depends on the maximum motor temperature)
Poles2
Insulation classF
Protection degreeIP 68
VoltageSingle-phase 1~230V +6-10% OYM
Three-phase 3~400V +6-10% OY
Single-phase 1~230V ±6% WYM
Three-phase 3~400V ±6% WY
Max. immersion150 m
Max. sand content150 g/m3

Material Pump 4WN

ImpellerPPO reinforced with glass fibres
ShaftStainless steel AISI 304 (EN 1.4301)
Outer casingAISI 304 (EN 1.4301)
Discharge casingAISI 304 (EN 1.4301)
Motor connectionAISI 304 (EN 1.4301)

pump 4WN

4” submersible centrifugal pump
4” submersible centrifugal electric pump in AISI 304 with a thick outer stainless steel casing, the discharge casing and the lower support are made of micro-cast stainless steel, the stainless steel non-return valve, as well as the stages, the pump shaft, the coupling joint and the stainless steel filter grid. Floating Noryl impellers and glass fibre reinforced polycarbonate diffusers. Motor coupling in accordance with the NEMA standards. Particularly recommended for the movement of clear water in wells, the pressurisation of clean water for agricultural, domestic or industrial use, or for the irrigation and movement of water in gene.

PERFORMANCE CURVE SPECIFICATIONS
The specifications below qualify the curves shown on the following pages.
Tolerances according to ISO 9906 Annex A
The curves refer to effective speed of asynchronous motors at 50 Hz
Measurements were carried out with clean water at 20°C of temperature and with a kinematic viscosity
of  = 1 mm2/s (1 cSt)
The continuous curves indicate the recommended working range. The dotted curve is only a guide.
In order to avoid the risk of over-heating, the pumps should not be used at a flow rate below 10% of bestefficiency point.

Symbols explanation:
Q = volume flow rate
H = total head
P2 = pump power input (shaft power)
 = pump efficiency
NPSH = net positive suction head required by the pump
MEI = minimum efficiency index

The minimun efficiency index (MEI) is a measure of the quality of a pump size in respect to its mean efficiency. The minimum efficiency index is based on the hydraulic efficiency and on the head at the best efficiency point.
The efficiency of a pump with trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. The operation of these water pumps with variabile duty points may be more efficient end economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system

Technical

  • Total head from 3 to 289 m
  • Capacity from 0.3 to 24 m3/h
  • Maximum immersion 150 m
  • Maximum liquid temperature 35°C
  • Maximum sand content 50 gr/m3
  • MEI > 0.4 (from 4WN1 to 4WN5)
characteristic-pump-4WN-ebara
Pump typePOWERQ=Capacity
­­KWHPl/min 0510152025
m/h 00.30.60.91.21.5
H=Total head
4WN1-100.370.50676355463318
4WN1-130.370.50867870564223
4WN1-190.550.75126118105866030
4WN1-260.7511731601411178139
4WN1-381.101.5025323420816911752

 

Pump typePOWERQ=Capacity
­­KWHPl/min 0152025303540
m/h 00.91.21.51.82.12.4
H=Total head
4WN2-50.370.5034323129272523
4WN2-70.370.5046434239363329
4WN2-100.550.7567646158544943
4WN2-140.750.1092868379746760
4WN2-201.101.5013913112712011110190

 

Pump typePOWERQ=Capacity
­­KWHPl/min 0202530354045506070
m/h 01.21.51.82.12.42.733.64.2
H=Total head
4WN3-50.370.5034323130292725231811
4WN3-80.550.7554515049464341383019
4WN3-110.75172686664615854493826
4WN3-161.101.501061019895898377705433
4WN3-211.5021421351321271221151081007949
4WN3-322.20320820019418717716515213810462
Pump typePOWERQ=Capacity
­­KWHPl/min 025303540455060708090100
m/h 01.51.82.12.42.733.64.24.85.46
H=Total head
4WN4-50.370.503329282726252421181383
4WN4-70.550.7546434241393836332822157
4WN4-90.751595554525149474337282010
4WN4-141.101.50938786838179766858473320
4WN4-181.502120113111108105102988875604225
4WN4-272.203175164161157152147141127109876135
4WN4-35342282122082031971911841661451198546
4WN4-443.7052822612552492412332232011731409952
4WN4-4845.5030928928327626725824822519716212073