HPK-pump-KSB
HPK-pump-KSB

Main applications hpk

  • Auxiliary Systems
  • Boiler feed systems
  • Building services
  • Cooling water and condensate
  • District heating
  • Energy
  • Heating / ventilation / air-condition
  • Industry engineering
  • Nuclear Power Stations
  • Power Stations < 100 MW
  • Power Stations > 100 MW
  • Special processes
  • Steam and hot water, district heating

Design hpk

Horizontal radially split volute casing pump in back pull-out design, with radial impeller, single-entry, single-stage, to ISO 2858 / ISO 5199. Optional TRD type testing by TÜV. ATEX-compliant version available.

Application pump hpk

Pumping hot water and thermal oil in piping systems or tank systems, particularly in medium-sized and large hot-water heating systems, forced circulation boilers, district heating systems

Technical data

  • Q max 4,800.0 m³/h
  • H max 275.0 m

Fields of Application hpk

HPK pumps in standard design are used for plants where hot water thermal oils must be transported in pipeline or tank systems, particularly in  medium-sized and large heating systems, forced circulation boilers, district heating systems and similar.

HPK-E and HPK-E4 have been type-tested to TRD (German Steam Boiler Regulations) by TÜV (Technical Control Board).
Type test certificates can be offered and supplied on request.

Desing Details pump hpk

Impeller:

reduced axial thrust and shaft seal balancing due to back vanes.

Casing

Radially split, consisting of volute casing and discharge cover.
HPK-S with casing wear ring, HPK-E without casing wear ring.
Double volute depending on the pump size.

Balancing

Axial thrust is balanced by means of back vanes

Rotor and bearings

are dimensioned so as to ensure a shaft deflection below 0.05 mm and a bearing life of more than 17500 operating hours

Overview of technical data hpk

Q (50Hz)1.0 – 4,800.0 (m³/h)
H (50Hz)2.0 – 275.0 (m)
Type of bearingRolling element bearings
Casing partitionRadially split
Drive frequency50 Hz /60 Hz
Type of driveElectric motor
Drive voltageLow voltage
No. of impeller entriesSingle entry
Impeller material (EN standard)JS 1030, JL 1040, 1.4408
Type of installationLong-coupled
Type of couplingDirect
Type of lubricationOil lubrication
Max. permissible fluid temperature240.0 (°C)
Nozzle positionEnd suction
Maximum operating pressurePN 40
Pull-out designYes
Pump set locationDry installed
Shaft material (EN standard)C45+N
Suction characteristicsNon-priming
Type of casingVolute casing
Type of impellerRadial, Closed
Type of connectionFlange
Casing material (EN standard)JS 1025, 1.7706, GP240GH+N
eClass assignment36410000, 36410100, 36410101
Installation positionHorizontal
Shaft seal typeMechanical seal, Gland packing
Main applicationsIndustry and process engineering, Energy, Building services
Casing materialCast steel, Nodular cast iron
Maximum discharge-side pressure40.0 (bar)
Maximum drive rating3200.0 (kW)
Type of installationStationary
Maximum speed of rotation3500.0 (1/min)