Main applications hpk
- Auxiliary Systems
- Boiler feed systems
- Building services
- Cooling water and condensate
- District heating
- Energy
- Heating / ventilation / air-condition
- Industry engineering
- Nuclear Power Stations
- Power Stations < 100 MW
- Power Stations > 100 MW
- Special processes
- Steam and hot water, district heating
Design hpk
Horizontal radially split volute casing pump in back pull-out design, with radial impeller, single-entry, single-stage, to ISO 2858 / ISO 5199. Optional TRD type testing by TÜV. ATEX-compliant version available.
Application pump hpk
Pumping hot water and thermal oil in piping systems or tank systems, particularly in medium-sized and large hot-water heating systems, forced circulation boilers, district heating systems
Technical data
- Q max 4,800.0 m³/h
- H max 275.0 m
Fields of Application hpk
HPK pumps in standard design are used for plants where hot water thermal oils must be transported in pipeline or tank systems, particularly in medium-sized and large heating systems, forced circulation boilers, district heating systems and similar.
HPK-E and HPK-E4 have been type-tested to TRD (German Steam Boiler Regulations) by TÜV (Technical Control Board).
Type test certificates can be offered and supplied on request.
Desing Details pump hpk
Impeller:
reduced axial thrust and shaft seal balancing due to back vanes.
Casing
Radially split, consisting of volute casing and discharge cover.
HPK-S with casing wear ring, HPK-E without casing wear ring.
Double volute depending on the pump size.
Balancing
Axial thrust is balanced by means of back vanes
Rotor and bearings
are dimensioned so as to ensure a shaft deflection below 0.05 mm and a bearing life of more than 17500 operating hours
Overview of technical data hpk
| Q (50Hz) | 1.0 – 4,800.0 (m³/h) |
| H (50Hz) | 2.0 – 275.0 (m) |
| Type of bearing | Rolling element bearings |
| Casing partition | Radially split |
| Drive frequency | 50 Hz /60 Hz |
| Type of drive | Electric motor |
| Drive voltage | Low voltage |
| No. of impeller entries | Single entry |
| Impeller material (EN standard) | JS 1030, JL 1040, 1.4408 |
| Type of installation | Long-coupled |
| Type of coupling | Direct |
| Type of lubrication | Oil lubrication |
| Max. permissible fluid temperature | 240.0 (°C) |
| Nozzle position | End suction |
| Maximum operating pressure | PN 40 |
| Pull-out design | Yes |
| Pump set location | Dry installed |
| Shaft material (EN standard) | C45+N |
| Suction characteristics | Non-priming |
| Type of casing | Volute casing |
| Type of impeller | Radial, Closed |
| Type of connection | Flange |
| Casing material (EN standard) | JS 1025, 1.7706, GP240GH+N |
| eClass assignment | 36410000, 36410100, 36410101 |
| Installation position | Horizontal |
| Shaft seal type | Mechanical seal, Gland packing |
| Main applications | Industry and process engineering, Energy, Building services |
| Casing material | Cast steel, Nodular cast iron |
| Maximum discharge-side pressure | 40.0 (bar) |
| Maximum drive rating | 3200.0 (kW) |
| Type of installation | Stationary |
| Maximum speed of rotation | 3500.0 (1/min) |