2GP-CVM-pump-Ebara
2GP-CVM-pump-Ebara

About booster pump 2gp cvm

Booster sets with two vertical multi-stage pumps

Two CVM series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump for the 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).

Features

  • Water supply for building service
  • Water supply for Industry
  • Irrigation

Application 2gp cvm

• Maximum liquid temperature: 40°C
• Maximum operating pressure: 10 bar
• Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or  less), no gas or corrosive and  aggressive substances
• Maximum chlorine content: 500 ppm
• Altitude not exceeding 1000 m a.s.l.;
• Humidity 50% without  condensation
• Ambient protected against atmospheric agents.

Material booster pump 2gp cvm

• Cast iron pump body and motor support
• External casing in AISI 304
• Impeller, stages and diffuser in glass fibre reinforced technopolymer impeller
• Shaft in AISI 416
• Mechanical seal in Ceramic/Carbon/EPDM

Techanical data booster pump 2gp cvm

• IE3 motor starting from 0.75kW
• Self-ventilated 2-pole asynchronous motor
• Class of insulation F
• IP44 Protection degree
• Single-phase voltage 230V ±10% 50Hz,Threephase
voltage 400V ±10% 50Hz

Model KW HP Q=Capacity
I/min 40 60 80 100 120 160 200 240
m/h 2.4 3.6 4.8 6.0 7.2 9.6 12.0 14.4
H=Total head
2GP CVM A/8 M 0.6+0.6 0.8+0.8 42.5 39.4 35.6 31.1 25.9 12.8
2GP CVM A/10 M 0.75+0.75 1+1 57.5 54.0 49.5 43.5 36.6 19.5
2GP CVM A/12 M 0.9+0.9 1.2+1.2 69.0 65.0 59.5 52.5 44.0 23.4
2GP CVM A/15 M 1.1+1.1 1.5+1.5 80.5 75.5 69.5 61.0 51.0 27.3
2GP CVM A/18 M 1.3+1.3 1.8+1.8 94.5 88.0 80.0 70.0 58.5 28.8
2GP CVM B/10 M 0.75+0.75 1+1 36.2 35.1 33.7 32.0 27.5 21.6 14.7
2GP CVM B/12 M 0.9+0.9 1.2+1.2 48.0 46.8 45.0 42.6 36.6 28.8 19.6
2GP CVM B/15 M 1.1+1.1 1.5+1.5 60.5 58.5 56.2 53.3 45.8 36.0 24.5
2GP CVM B/20 M 1.5+1.5 2+2 74.0 72.0 69.0 65.5 56.0 44.5 30.6
2GP CVM B/23 M 1.7+1.7 2.3+2.3 86.0 84.0 80.5 76.5 65.5 51.5 35.7
2GP CVM B/25 1.85+1.85 2.5+2.5 98.5 96.0 92.0 87.0 74.5 59.0 41.0
Model KW HP Q=Capacity
I/min 40 60 80 100 120 160 200 240
m/h 2.4 3.6 4.8 6.0 7.2 9.6 12.0 14.4
H=Total head
2GP CVM A/10 M 0.75+0.75 1+1 57.5 54.0 49.5 43.5 36.6 19.5
2GP CVM A/12 M 0.9+0.9 1.2+1.2 69.0 65.0 59.5 52.5 44.0 23.4
2GP CVM A/15 M 1.1+1.1 1.5+1.5 80.5 75.5 69.5 61.0 51.0 27.3 –  
 
Model KW HP Q=Capacity
I/min 40 60 80 100 120 160 200 240
m/h 2.4 3.6 4.8 6.0 7.2 9.6 12.0 14.4
H=Total head
2GP CVM B/12 M 0.9+0.9 1.2+1.2   48.0 46.8 45.0 42.6 36.6 28.8 19.6
2GP CVM B/15 M 1.1+1.1 1.5+1.5   60.5 58.5 56.2 53.3 45.8 36.0 24.5
2GP CVM B/20 M 1.5+1.5 2+2   74.0 72.0 69.0 65.5 56.0 44.5 30.6
2GP CVM B/23 M 1.7+1.7 2.3+2.3   86.0 84.0 80.5 76.5 65.5 51.5 35.7