Booster sets with two horizontal cast iron multi-stage pumps
Two COMPACT series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump for the 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
Features
- Water supply for building service
- Water supply for Industry
- Irrigation
Application booster pump 2gp compact
• Maximum liquid temperature: 40°C
• Maximum operating pressure: 10 bar
• Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
• Maximum chlorine content: 500 ppm
• Altitude not exceeding 1000 m a.s.l.;
• Humidity 50% without condensation
• Ambient protected against atmospheric agents.
Material booster pump 2gp compact
• Cast iron pump body
• Shaft in AISI 416
• Glass fibre reinforced technopolymer impeller
• Mechanical seal in Ceramic/Carbon/NBR
Technical data booster pump 2gp compact
• IE3 motor starting from 0.75kW
• Self-ventilated 2-pole asynchronous motor
• Class of insulation F
• IP44 Protection degree
• Single-phase voltage 230V ±10% 50Hz,Threephase
voltage 400V ±10% 50Hz
Model |
KW |
HP |
Q=Capacity |
||||||||
I/min |
40 |
80 |
100 |
120 |
160 |
200 |
240 |
|
|||
m/h |
2.4 |
4.8 |
6.0 |
7.2 |
9.6 |
12.0 |
14.4 |
|
|||
H=Total head |
|||||||||||
2GP Compact A/8 M |
0.6+0.6 |
0.8+0.8 |
|
39.7 |
36.1 |
27.4 |
22.4 |
10.5 |
– |
– |
|
2GP Compact A/10 M |
0.75+0.75 |
1+1 |
|
56.5 |
53.0 |
43.5 |
37.1 |
20.0 |
– |
– |
|
2GP Compact A/12 M |
0.9+0.9 |
1.2+1.2 |
|
67.5 |
63.5 |
52.5 |
45.0 |
24.0 |
– |
– |
|
2GP Compact A/15 M |
1.1+1.1 |
1.5+1.5 |
|
79.0 |
74.5 |
62.5 |
54.0 |
28.0 |
– |
– |
|
2GP Compact B/12 M |
0.9+0.9 |
1.2+1.2 |
|
– |
47.5 |
43.5 |
41.5 |
35.2 |
27.6 |
18.0 |
|
2GP Compact B/15 M |
1.1+1.1 |
1.5+1.5 |
|
– |
58.0 |
54.0 |
51.5 |
44.5 |
34.5 |
22.0 |
|
Model |
KW |
HP |
Q=Capacity |
||||||||
I/min |
40 |
80 |
100 |
120 |
160 |
200 |
240 |
|
|||
m/h |
2.4 |
4.8 |
6.0 |
7.2 |
9.6 |
12.0 |
14.4 |
|
|||
H=Total head |
|||||||||||
2GP Compact A/8 M |
0.6+0.6 |
0.8+0.8 |
|
39.7 |
36.1 |
27.4 |
22.4 |
10.5 |
– |
– |
|
2GP Compact A/10 M |
0.75+0.75 |
1+1 |
|
56.5 |
53.0 |
43.5 |
37.1 |
20.0 |
– |
– |
|
2GP Compact A/12 M |
0.9+0.9 |
1.2+1.2 |
|
67.5 |
63.5 |
52.5 |
45.0 |
24.0 |
– |
– |
|
Model |
KW |
HP |
Q=Capacity |
||||||||
I/min |
60 |
80 |
100 |
120 |
160 |
200 |
240 |
|
|||
m/h |
3.6 |
4.8 |
6.0 |
7.2 |
9.6 |
12.0 |
14.4 |
|
|||
H=Total head |
|||||||||||
2GP Compact B/12 M |
0.9+0.9 |
1.2+1.2 |
|
47.5 |
46.0 |
43.5 |
41.5 |
35.2 |
27.6 |
18.0 |
|
2GP Compact B/15 M |
1.1+1.1 |
1.5+1.5 |
|
58.0 |
56.0 |
54.0 |
51.5 |
44.5 |
34.5 |
22.0 |
|