Main applications rvm
- Energy
- Nuclear Island
- Nuclear Power Stations
Technical data
- Q max 50.0 m³/h
- H max 2,000.0 m
Design rvm
Vertical multistage barrel pull-out pump.
Application pump rvm
Core flooding, emergency cooling and residual heat removal systems, chemical and volume control systems, high-pressure and medium-pressure safety injection systems.
Overview of technical data rvm
| Q (50Hz) | 0.0 – 50.0 (m³/h) |
| H (50Hz) | 0.0 – 2,000.0 (m) |
| Drive frequency | 50 Hz /60 Hz |
| Max. permissible fluid temperature | 100.0 (°C) |
| Standard | ASME SECT. III, KTA |
| Installation position | Vertical |
| Shaft seal type | Mechanical seal |
| Main applications | Energy |
| Maximum discharge-side pressure | 200.0 (bar) |
| Maximum speed of rotation | 6000.0 (1/min) |