Main applications rvr
- Energy
- Nuclear Island
- Nuclear Power Stations
Technical data
- Q max 6,000.0 m³/h
- H max 190.0 m
Design rvr
Vertical annular casing pump with forged or cast pressure boundary and diffuser.
Application pump rvr
Core flooding, emergency cooling and residual heat removal systems, ancillary systems, acid feed system and low-pressure injection system, component cooling water systems
Overview of technical data rvr
Q (50Hz) | 0.0 – 6,000.0 (m³/h) |
H (50Hz) | 0.0 – 190.0 (m) |
Drive frequency | 50 Hz /60 Hz |
Type of drive | Electric motor |
Max. permissible fluid temperature | 200.0 (°C) |
Standard | ASME SECT. III, KTA |
Installation position | Vertical |
Shaft seal type | Mechanical seal |
Main applications | Energy |
Maximum discharge-side pressure | 63.0 (bar) |
Maximum speed of rotation | 3600.0 (1/min) |